OK, I've tried a bunch of stuff but I continue to get S0C7 using sqrt,
so I must not be understanding what the input to the sqrt function
should look like. ;-) Please give me some pointers.
Here's the log:
pipe literal 16 | strip | specs a: 1.2 . if a>0 then set #1:=sqrt(a)
endif print #1 1 | console
FPLINX410E ABEND 000000C7 at 02CD89A6; PSW 03EC0000 82CD89A6 00060007
FPLINX411I ... In SQRT; offset 0000368E in FPLSPV 06/22/18 11.41
FPLINX412I ... GPR0: 0000000E 02CD5868 7F27AFA8 00000002
FPLINX412I ... GPR4: 7F27AFA8 00000002 7F27AFC0 7F27B2E4
FPLINX412I ... GPR8: 7F27EC3F 7F27B6F8 7F278DA8 7F2781B0
FPLINX412I ... GPRC: 82CD898E 7F278E68 82CD61C4 02CD8988
FPLINX413I ... Store 02CD899C: 98E1F00C F9F07004 C9BE47B0 C0381F00 41100531
FPLINX1198I Stage is active
FPLMSG003I ... Issued from stage 4 of pipeline 1
FPLMSG001I ... Running "specs a: 1.2 . if a>0 then set #1:=sqrt(a) endif"
DMSABE141T Data exception occurred at 82CD89A6 in routine PIPE
CMS