Doug,

Did an Isotherm 2501 in my 35/3 last year.  Hardest part was running a wire
from the breaker to the lazarette for the compressor.  I made a shelf fo
the compressor out of plywood and epoxied it, only because I had some epoxy
laying around.  I drilled 2 holes in the back of the icebox for the copper
lines and used a can of foam from Home Depot to fill them.  Attached the
evaporater with spacers and screws.

Joel
35/3
The Office

On Wednesday, January 22, 2014, Doug Allardyce <[email protected]>
wrote:

> All,
> I'm in the process of updating a 1985 C&C 35 MK 3. One of my projects is
> installing a refrigeration unit. As I'm in the planning phase, I'm looking
> to hear from anyone who has already done an installation. I would be
> interested to know what unit was selected, and how it was installed. If
> anyone has pictures that would be great
>
> Doug Allardyce
> 1985 C&C 35 MK III "Bullet"
> Detroit
> ~~~~~~~~_/)~~~_/) ~~~~~~~~
>
>
>
>

-- 
Joel
301 541 8551
_______________________________________________
This List is provided by the C&C Photo Album
http://www.cncphotoalbum.com
[email protected]

Reply via email to