Dennis, Agree with the 30 micron and 10 micron filter choices. When I worked for Verizon, we found those numbers worked best. The lower 2 micron just causes flow issues and nuisance shutdown. I think Nigel Calder recommends 30 and 10 microns.
Correct me if I'm wrong. I thought the Racor turbine type water separater required that it be first in line to work well ( making it the primary) and the second filter the fuel passes through is called the secondary filter. Do I have that backward? Chuck Resolute 1990 C&C 34R Broad Creek, Magothy River, Md ----- Original Message ----- From: "Dennis C. via CnC-List" <[email protected]> To: "CnClist" <[email protected]> Cc: "Dennis C." <[email protected]> Sent: Wednesday, August 5, 2015 3:56:10 PM Subject: Stus-List Fuel filters - micron size While we're discussing fuel filters, I recently read a blurb under a filter element description for Racor turbine type filters recommending 30 micron for water separation/primary filtration, 10 micron for primary without water separation and 2 micron for secondary filtration. Based on that, I have switched from 10 to 30 micron elements in my Racor 500MA. However, I have not been able to find that guidance anywhere on the Racor site. Dennis C. Touche' 35-1 #83 Mandeville, LA _______________________________________________ Email address: [email protected] To change your list preferences, including unsubscribing -- go to the bottom of page at: http://cnc-list.com/mailman/listinfo/cnc-list_cnc-list.com
_______________________________________________ Email address: [email protected] To change your list preferences, including unsubscribing -- go to the bottom of page at: http://cnc-list.com/mailman/listinfo/cnc-list_cnc-list.com