You can do one of the following:
- Raise the mounting of the water witch.
- Use a smaller diameter, or shorter hose

Check valves are designed for preventing instantaneous backflow.
Pretty much all of them will eventually leak the water back into the bilge,
so you will still cycle, only with a longer period.
If you want to go that road, you can install a normally closed valve that
opens when the bilge pump comes on.
However, this adds complication to the system which is never a good thing.
I prefer a small bilge pump (500 gph) with a small diameter (3/8 id) hose
to keep the bilge dry, and a larger (2000 gph) one (1-1/2 id) with a higher
float switch if more pumping is needed.
Ahmet
Boston, MA

On Sat, Jan 2, 2016 at 4:52 PM, Joel Aronson via CnC-List <
cnc-list@cnc-list.com> wrote:

> I replaced my automatic bilge pump switch with a waterwhich. When the when
> the switch activates the bilge pump, the bilge is pumped relatively dry.
> However when the pump shuts off water flows back into the bilge and so the
> pump is running in an endless loop. I see my alternatives as installing a
> check valve or installing a different brand of switch. I believe I
> previously had a Johnson switch.
>
>  any recommendations
> Joel
> 35/3
> Annapolis
>
>
> --
> Joel
> 301 541 8551
>
> _______________________________________________
>
> Email address:
> CnC-List@cnc-list.com
> To change your list preferences, including unsubscribing -- go to the
> bottom of page at:
> http://cnc-list.com/mailman/listinfo/cnc-list_cnc-list.com
>
>
>
_______________________________________________

Email address:
CnC-List@cnc-list.com
To change your list preferences, including unsubscribing -- go to the bottom of 
page at:
http://cnc-list.com/mailman/listinfo/cnc-list_cnc-list.com