I tried to configure sensors plugin on a dom0 server running debian lenny. I can see sensors.so plugin file on lib folder. I also installed and configure lm-sensors and it seems to be working:
vpsxx:/usr/local/src/# sensors coretemp-isa-0000 Adapter: ISA adapter Core 0: +49.0°C (high = +76.0°C, crit = +100.0°C) coretemp-isa-0001 Adapter: ISA adapter Core 1: +49.0°C (high = +76.0°C, crit = +100.0°C) coretemp-isa-0002 Adapter: ISA adapter Core 2: +45.0°C (high = +76.0°C, crit = +100.0°C) coretemp-isa-0003 Adapter: ISA adapter Core 3: +48.0°C (high = +76.0°C, crit = +100.0°C) w83627dhg-isa-06e0 Adapter: ISA adapter VCore: +0.88 V (min = +0.00 V, max = +1.74 V) in1: +10.14 V (min = +8.55 V, max = +6.76 V) ALARM AVCC: +3.06 V (min = +2.35 V, max = +3.60 V) 3VCC: +3.06 V (min = +0.70 V, max = +2.05 V) ALARM in4: +0.98 V (min = +0.87 V, max = +0.72 V) ALARM in5: +1.38 V (min = +1.99 V, max = +0.64 V) ALARM in6: +1.10 V (min = +5.32 V, max = +0.31 V) ALARM VSB: +3.06 V (min = +2.14 V, max = +1.15 V) ALARM VBAT: +3.01 V (min = +3.10 V, max = +3.36 V) ALARM Case Fan: 0 RPM (min = 10546 RPM, div = 128) ALARM CPU Fan: 1068 RPM (min = 1188 RPM, div = 16) ALARM Aux Fan: 1406 RPM (min = 0 RPM, div = 16) ALARM fan4: 0 RPM (min = 2109 RPM, div = 128) ALARM Sys Temp: +44.0°C (high = -48.0°C, hyst = -83.0°C) ALARM sensor = diode CPU Temp: +53.0°C (high = +80.0°C, hyst = +75.0°C) sensor = diode AUX Temp: -128.0°C (high = +80.0°C, hyst = +75.0°C) sensor = diode cpu0_vid: +2.050 V This is my collectd.conf: LoadPlugin network Hostname vpsxx.domain FQDNLookup true Interval 30 <Plugin network> Server "8x.2xx.1xx.xx" "25826" </Plugin> LoadPlugin cpu LoadPlugin df LoadPlugin disk LoadPlugin interface LoadPlugin load LoadPlugin memory LoadPlugin swap LoadPlugin syslog LoadPlugin hddtemp LoadPlugin sensors <Plugin "sensors"> Sensor "w83627dhg-isa-06e0/temperature-temp1" Sensor "w83627dhg-isa-06e0/temperature-temp2" Sensor "w83627dhg-isa-06e0/fanspeed-fan1" Sensor "w83627dhg-isa-06e0/fanspeed-fan2" </Plugin> <Plugin "hddtemp"> Host "127.0.0.1" Port "7634" TranslateDevicename false </Plugin> <Plugin "syslog"> LogLevel "notice" </Plugin> After restarting collectd I see this error: Oct 1 15:16:38 vpsxx collectdmon[24278]: Warning: restarting collectd Oct 1 15:16:38 vpsxx collectdmon[24278]: Warning: collectd terminated with exit status 127 Oct 1 15:16:38 vpsxx collectdmon[24278]: Warning: restarting collectd Oct 1 15:16:38 vpsxx collectdmon[24278]: Warning: collectd terminated with exit status 127 Oct 1 15:16:38 vpsxx collectdmon[24278]: Warning: restarting collectd Oct 1 15:16:38 vpsxx collectdmon[24278]: Warning: collectd terminated with exit status 127 Any ideas? -- Regards; Israel Garcia _______________________________________________ collectd mailing list [email protected] http://mailman.verplant.org/listinfo/collectd