Hi list, Trying to collect thresholds for a switch's SFP sensors.
The data is stored in 4 OID's, low and high minor and major values with indexes 1 through 4 for each sensor. CISCO-ENTITY-SENSOR-MIB::entSensorThresholdValue.1067.1 = INTEGER: 900 CISCO-ENTITY-SENSOR-MIB::entSensorThresholdValue.1067.2 = INTEGER: 800 CISCO-ENTITY-SENSOR-MIB::entSensorThresholdValue.1067.3 = INTEGER: 40 CISCO-ENTITY-SENSOR-MIB::entSensorThresholdValue.1067.4 = INTEGER: 20 CISCO-ENTITY-SENSOR-MIB::entSensorThresholdValue.1068.1 = INTEGER: -60 CISCO-ENTITY-SENSOR-MIB::entSensorThresholdValue.1068.2 = INTEGER: -70 CISCO-ENTITY-SENSOR-MIB::entSensorThresholdValue.1068.3 = INTEGER: -150 CISCO-ENTITY-SENSOR-MIB::entSensorThresholdValue.1068.4 = INTEGER: -160 The references are to the port and sensor name. ENTITY-MIB::entPhysicalDescr.1067 = STRING: FastEthernet0/5 Bias Current Sensor ENTITY-MIB::entPhysicalDescr.1068 = STRING: FastEthernet0/5 Transmit Power Sensor I have tried different things config-wise but it seems collectd isn't proceeding to the next OID correctly after a snmp getnext. And just loops over the same value infinitely: 22.985041 collectd -> switch SNMP get-next-request 1.3.6.1.4.1.9.9.91.1.2.1.1.4.1034.4 22.987180 switch -> collectd SNMP get-response 1.3.6.1.4.1.9.9.91.1.2.1.1.4.1035.1 22.987234 collectd -> switch SNMP get-next-request 1.3.6.1.4.1.9.9.91.1.2.1.1.4.1034.4 22.989948 switch -> collectd SNMP get-response 1.3.6.1.4.1.9.9.91.1.2.1.1.4.1035.1 22.990028 collectd -> switch SNMP get-next-request 1.3.6.1.4.1.9.9.91.1.2.1.1.4.1034.4 22.992522 switch -> collectd SNMP get-response 1.3.6.1.4.1.9.9.91.1.2.1.1.4.1035.1 Not sure either if collectd would store the results in any meaningful way. Is it possible to solve this? (Using collectd 5.0.3 currently) Best regads, Stian Øvrevåge _______________________________________________ collectd mailing list [email protected] http://mailman.verplant.org/listinfo/collectd