On 10/20/2014 04:52 PM, Jan Kundrát wrote:
On Friday, 17 October 2014 11:29:24 CEST, adnane wrote:
while monitoring some cisco switchs with the snmp plugin, I had the
uptime in Timeticks format,
which, I found needs to be devided by 100 to translate it to seconds,
and even if I see the the
support for the Timeticks was added to collectd since v4.1.2, I can't
find how to configure it,
nor add it to types.db, any help plz.
<Data "uptime">
Type "uptime"
Table false
Instance "uptime"
Values "DISMAN-EVENT-MIB::sysUpTimeInstance" Scale 0.01
</Data>