ashb commented on a change in pull request #16301:
URL: https://github.com/apache/airflow/pull/16301#discussion_r658614278



##########
File path: airflow/jobs/local_task_job.py
##########
@@ -78,16 +79,11 @@ def _execute(self):
         def signal_handler(signum, frame):
             """Setting kill signal handler"""
             self.log.error("Received SIGTERM. Terminating subprocesses")
-            self.on_kill()
             self.task_instance.refresh_from_db()
-            if self.task_instance.state not in State.finished:
-                self.task_instance.set_state(State.FAILED)
-            self.task_instance._run_finished_callback(  # pylint: 
disable=protected-access
-                error="task received sigterm"
-            )
-            raise AirflowException("LocalTaskJob received SIGTERM signal")
+            os.kill(self.task_instance.pid, signum)

Review comment:
       I dont understand this change.
   
   on_kill called task_runner.terminate which terminates the process and tidies 
up afterwards.
   
   In the case of run_as_user, task_instance.pid will be a different user and 
thus _we won't be able to send it the kill signal_.




-- 