https://issues.apache.org/jira/browse/BEAM-1716?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15982824#comment-15982824
]
Tobias Feldhaus commented on BEAM-1716:
---------------------------------------
Example to reproduce:
https://github.com/james-woods/beam_pipeline/commit/bf6d8a2e83db9913e3d4b67f0c3f6beaef1cc41c
> Using Instant type in TableRow should map to the right output format for
> TIMESTAMP in BigQuery
> ----------------------------------------------------------------------------------------------
>
> Key: BEAM-1716
> URL: https://issues.apache.org/jira/browse/BEAM-1716
> Project: Beam
> Issue Type: Bug
> Components: sdk-java-gcp
> Affects Versions: 0.5.0
> Reporter: Tobias Feldhaus
> Labels: newbie, starter
> Fix For: First stable release
>
>
> When using an Instant type in a TableRow, and a TIMESTAMP field in the
> TableFieldSchema, one has to convert the Instant via
> instant.getMillis() / 1000
> to match the BigQuery TIMESTAMP that is "A positive or negative decimal
> number. A positive number specifies the number of seconds since the epoch".
> In the Dataflow 1.9 SDK this conversion is done automatically.
--
This message was sent by Atlassian JIRA