https://issues.apache.org/jira/browse/BEAM-5110?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16580554#comment-16580554
 ] 

Ankur Goenka commented on BEAM-5110:
------------------------------------

With the worker_id introduction, fn_api is capable of supporting and managing 
multiple SDKHarness on a single machine. 

The challenge with python is that a single python process and only use 1 cpu 
core.

Going forward there can be other cases where we might want to have more than 1 
instance of the same SDKHarness environment.

But this seems to be a separate problem and should be handled separately from 
the current issue.

> Reconile Flink JVM singleton management with deployment
> -------------------------------------------------------
>
>                 Key: BEAM-5110
>                 URL: https://issues.apache.org/jira/browse/BEAM-5110
>             Project: Beam
>          Issue Type: Bug
>          Components: runner-flink
>            Reporter: Ben Sidhom
>            Assignee: Ben Sidhom
>            Priority: Major
>          Time Spent: 2h 10m
>  Remaining Estimate: 0h
>
> [~angoenka] noticed through debugging that multiple instances of 
> BatchFlinkExecutableStageContext.BatchFactory are loaded for a given job when 
> executing in standalone cluster mode. This context factory is responsible for 
> maintaining singleton state across a TaskManager (JVM) in order to share SDK 
> Environments across workers in a given job. The multiple-loading breaks 
> singleton semantics and results in an indeterminate number of Environments 
> being created.
> It turns out that the [Flink classloading 
> mechanism|https://ci.apache.org/projects/flink/flink-docs-release-1.5/monitoring/debugging_classloading.html]
>  is determined by deployment mode. Note that "user code" as referenced by 
> this link is actually the Flink job server jar. Actual end-user code lives 
> inside of the SDK Environment and uploaded artifacts.
> In order to maintain singletons without resorting to IPC (for example, using 
> file locks and/or additional gRPC servers), we need to force non-dynamic 
> classloading. For example, this happens when jobs are submitted to YARN for 
> one-off deployments via `flink run`. However, connecting to an existing 
> (Flink standalone) deployment results in dynamic classloading.
> We should investigate this behavior and either document (and attempt to 
> enforce) deployment modes that are consistent with our requirements, or (if 
> possible) create a custom classloader that enforces singleton loading.



--
This message was sent by Atlassian JIRA
(v7.6.3#76005)