https://issues.apache.org/jira/browse/BEAM-569?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Jean-Baptiste Onofré updated BEAM-569:
--------------------------------------
Description:
When using JmsIO this way:
{code}
JmsIO.read().withConnectionFactory(connectionFactory).withQueue("queue")
{/code}
the user expects to work in unbounded mode. However, as the {{maxNumRecords}}
value is not set by default in {{JmsIO}}, the default value set is {{0}} (as
it's a {{long}}). It means that the {{JmsIO.read()}} just doesn't consume any
message and exit directly.
IMHO, it makes sense to define the {{maxNumRecords}} value to
{{Long.MAX_VALUE}} by default. Thanks to that, {{JmsIO.read()}} will really
work in unbounded form.
was:
Right now, the JMS IO source doesn't wait for new message on the JMS
destination (it uses {{receiveNoWait()}} method on the consumer).
I think, it's worth to give the possibility for the user to define the behavior.
I propose to introduce {{withTimeout()}} configuration on JMS IO:
- if the user defines {{-1}}, it means infinite timeout, so the reader will use
{{consumer.receive()}} and the source will wait for new messages on the
destination
- if the user defines {{0}}, it means the current behavior (and default): the
reader will use {{consumer.receiveNoWait()}}.
- if the user defines any positive value, it's actually the timeout to wait for
new messages: the reader will use {{consumer.receive(timeout)}}.
> JMS IO should set maxNumRecords to Long.MAX_VALUE by default
> ------------------------------------------------------------
>
> Key: BEAM-569
> URL: https://issues.apache.org/jira/browse/BEAM-569
> Project: Beam
> Issue Type: Improvement
> Components: sdk-java-extensions
> Reporter: Jean-Baptiste Onofré
> Assignee: Jean-Baptiste Onofré
> Fix For: 0.3.0-incubating
>
>
> When using JmsIO this way:
> {code}
> JmsIO.read().withConnectionFactory(connectionFactory).withQueue("queue")
> {/code}
> the user expects to work in unbounded mode. However, as the {{maxNumRecords}}
> value is not set by default in {{JmsIO}}, the default value set is {{0}} (as
> it's a {{long}}). It means that the {{JmsIO.read()}} just doesn't consume any
> message and exit directly.
> IMHO, it makes sense to define the {{maxNumRecords}} value to
> {{Long.MAX_VALUE}} by default. Thanks to that, {{JmsIO.read()}} will really
> work in unbounded form.
--
This message was sent by Atlassian JIRA
(v6.3.4#6332)