Tyler Hobbs created CASSANDRA-4573:
--------------------------------------
Summary: HSHA doesn't handle large messages gracefully
Key: CASSANDRA-4573
URL: https://issues.apache.org/jira/browse/CASSANDRA-4573
Project: Cassandra
Issue Type: Bug
Components: Core
Reporter: Tyler Hobbs
Assignee: Vijay
HSHA doesn't seem to enforce any kind of max message length, and when messages
are too large, it doesn't fail gracefully.
With debug logs enabled, you'll see this:
{{DEBUG 13:13:31,805 Unexpected state 16}}
Which seems to mean that there's a SelectionKey that's valid, but isn't ready
for reading, writing, or accepting.
Client-side, you'll get this thrift error (while trying to read a frame as part
of {{recv_batch_mutate}}):
{{TTransportException: TSocket read 0 bytes}}
--
This message is automatically generated by JIRA.
If you think it was sent incorrectly, please contact your JIRA administrators:
https://issues.apache.org/jira/secure/ContactAdministrators!default.jspa
For more information on JIRA, see: http://www.atlassian.com/software/jira