This is an automated email from the ASF dual-hosted git repository. ccollins pushed a commit to branch master in repository https://gitbox.apache.org/repos/asf/mynewt-core.git
commit f4244cf1448dbb29832d44fe60cc79f3e9fd71a2 Author: Christopher Collins <[email protected]> AuthorDate: Thu Nov 1 14:50:52 2018 -0700 hw/battery: Return error on failure in CLI cmds --- hw/battery/src/battery_shell.c | 88 +++++++++++++++++++++++++++++------------- 1 file changed, 61 insertions(+), 27 deletions(-) diff --git a/hw/battery/src/battery_shell.c b/hw/battery/src/battery_shell.c index 58acc1d..85b5bed 100644 --- a/hw/battery/src/battery_shell.c +++ b/hw/battery/src/battery_shell.c @@ -185,13 +185,14 @@ static void print_property(const struct battery_property *prop) static int cmd_bat_read(int argc, char **argv) { - int rc = 0; + int rc; int maxp; int i; struct battery_property *prop; if (argc < 2) { console_printf("Invalid number of arguments, use read <prop>\n"); + rc = SYS_EINVAL; goto err; } @@ -202,6 +203,7 @@ static int cmd_bat_read(int argc, char **argv) battery_prop_get_value(prop); if (!prop->bp_valid) { console_printf("Error reading property\n"); + rc = SYS_EIO; goto err; } print_property(prop); @@ -211,16 +213,21 @@ static int cmd_bat_read(int argc, char **argv) prop = battery_find_property_by_name(bat, argv[i]); if (prop == NULL) { console_printf("Invalid property name %s\n", argv[i]); + rc = SYS_EINVAL; goto err; } battery_prop_get_value(prop); if (!prop->bp_valid) { console_printf("Error reading property\n"); + rc = SYS_EIO; goto err; } print_property(prop); } } + + rc = 0; + err: return rc; } @@ -245,7 +252,7 @@ get_min_max(const struct battery_property *prop, long long *min, long long *max) static int cmd_bat_write(int argc, char ** argv) { - int rc = 0; + int rc; long long min; long long max; struct battery_property *prop; @@ -253,37 +260,49 @@ cmd_bat_write(int argc, char ** argv) if (argc < 3) { console_printf("Invalid number of arguments, use write <prop> <value>\n"); + rc = SYS_EINVAL; goto err; } prop = battery_find_property_by_name(bat, argv[1]); if (prop == NULL) { console_printf("Invalid property name %s\n", argv[1]); + rc = SYS_EINVAL; goto err; } + if (get_min_max(prop, &min, &max)) { console_printf("Property %s can not be set\n", argv[1]); + rc = SYS_EIO; goto err; } + val = parse_ll_bounds(argv[2], min, max, &rc); if (rc) { console_printf("Property value not in range <%lld, %lld>\n", min, max); rc = 0; goto err; } + if (prop->bp_type == BATTERY_PROP_VOLTAGE_NOW && (prop->bp_flags & BATTERY_PROPERTY_FLAGS_ALARM_THREASH) != 0) { - battery_prop_set_value_uint32(prop, (uint32_t)val); + rc = battery_prop_set_value_uint32(prop, (uint32_t)val); } else if (prop->bp_type == BATTERY_PROP_TEMP_NOW && (prop->bp_flags & BATTERY_PROPERTY_FLAGS_ALARM_THREASH) != 0) { - battery_prop_set_value_float(prop, val); + rc = battery_prop_set_value_float(prop, val); } else { console_printf("Property %s can't be written!\n", argv[1]); + rc = SYS_EINVAL; + goto err; } if (!prop->bp_valid) { console_printf("Error writing property!\n"); + rc = SYS_EIO; goto err; } + + rc = 0; + err: return rc; } @@ -309,17 +328,22 @@ static int cmd_bat_poll_rate(int argc, char **argv) int rc; uint32_t rate_in_s; - if (argc == 2) { - rate_in_s = (uint32_t)parse_ull_bounds(argv[1], 1, 255, &rc); - if (rc) { - console_printf("Invalid poll rate, use 1..255\n"); - } else { - battery_set_poll_rate_ms(bat, rate_in_s * 1000); - } - } else { + if (argc < 2) { console_printf("Missing poll rate argument\n"); + rc = SYS_EINVAL; + goto err; } - return 0; + + rate_in_s = (uint32_t)parse_ull_bounds(argv[1], 1, 255, &rc); + if (rc) { + console_printf("Invalid poll rate, use 1..255\n"); + goto err; + } + + rc = battery_set_poll_rate_ms(bat, rate_in_s * 1000); + +err: + return rc; } static int bat_property(struct battery_prop_listener *listener, @@ -336,34 +360,37 @@ static struct battery_prop_listener listener = { static int cmd_bat_monitor(int argc, char **argv) { - int rc = 0; + int rc; struct battery_property *prop; if (argc < 2) { console_printf("Invalid number of arguments, use monitor <prop_nam>\n"); + rc = SYS_EINVAL; goto err; } prop = battery_find_property_by_name(bat, argv[1]); if (prop == NULL) { if (strcmp(argv[1], "off") == 0) { - battery_prop_poll_unsubscribe(&listener, NULL); + rc = battery_prop_poll_unsubscribe(&listener, NULL); goto err; } console_printf("Invalid property name\n"); + rc = SYS_EINVAL; goto err; } if (argc == 3) { if (strcmp(argv[2], "off") == 0) { - battery_prop_poll_unsubscribe(&listener, prop); + rc = battery_prop_poll_unsubscribe(&listener, prop); goto err; } else if (strcmp(argv[2], "on") != 0) { console_printf("Invalid parameter %s\n", argv[2]); + rc = SYS_EINVAL; goto err; } } - battery_prop_poll_subscribe(&listener, prop); + rc = battery_prop_poll_subscribe(&listener, prop); err: return rc; @@ -394,19 +421,26 @@ static int bat_compat_cmd(int argc, char **argv) int rc; int i; - for (i = 0; bat_cli_commands[i].sc_cmd; ++i) + if (argc < 2) { - if (strcmp(bat_cli_commands[i].sc_cmd, argv[1]) == 0) - { - rc = bat_cli_commands[i].sc_cmd_func(argc - 1, argv + 1); - break; - } + rc = SYS_EINVAL; } - /* No command found */ - if (bat_cli_commands[i].sc_cmd == NULL) + else { - console_printf("Invalid command.\n"); - rc = -1; + for (i = 0; bat_cli_commands[i].sc_cmd; ++i) + { + if (strcmp(bat_cli_commands[i].sc_cmd, argv[1]) == 0) + { + rc = bat_cli_commands[i].sc_cmd_func(argc - 1, argv + 1); + break; + } + } + /* No command found */ + if (bat_cli_commands[i].sc_cmd == NULL) + { + console_printf("Invalid command.\n"); + rc = -1; + } } /* Print help in case of error */