PetteriAimonen commented on issue #10887: URL: https://github.com/apache/nuttx/issues/10887#issuecomment-1909782439
The [best master clock](https://en.wikipedia.org/wiki/Precision_Time_Protocol#Best_master_clock_algorithm) algorithm is used: https://github.com/apache/nuttx-apps/blob/master/netutils/ptpd/ptpd.c#L238 If the config is identical for boards, it picks based on MAC address of the network interface (lower address wins) -- This is an automated message from the Apache Git Service. To respond to the message, please log on to GitHub and use the URL above to go to the specific comment. To unsubscribe, e-mail: [email protected] For queries about this service, please contact Infrastructure at: [email protected]