xiaoxiang781216 commented on code in PR #20567:
URL: https://github.com/apache/nuttx/pull/20567#discussion_r4231769130
##########
include/nuttx/uorb.h:
##########
@@ -648,11 +648,23 @@
#define SENSOR_TYPE_CHARGE 65
+/* Inclinometer
+ * A sensor of this type returns the static inclination (tilt) of the
+ * device X, Y and Z axes relative to the horizontal plane, derived from
+ * the gravity vector. Each value is in degrees and signed, in the range
Review Comment:
why not reuse sensor_rotation? it's important to report the same data with
the same physical measement.
##########
include/nuttx/sensors/ioctl.h:
##########
@@ -264,6 +264,20 @@
#define SNIOC_SET_MOVING_AVG _SNIOC(0x006e)
+/* IOCTL commands unique to SCL3300 */
+
+/* Command: SNIOC_SET_OPERATIONAL_MODE
+ * Description: Select the operation mode
+ * Reuse from ISL29023
+ * Arg: enum scl3300_mode_e by value
+ */
+
+/* Command: SNIOC_SET_POWER_MODE
+ * Description: Select the idle power policy
+ * Reuse from LIS3DH
+ * Arg: enum scl3300_power_e by value
+ */
Review Comment:
but where they defined
##########
drivers/sensors/sensor.c:
##########
@@ -231,6 +231,7 @@ static const struct sensor_meta_s g_sensor_meta[] =
{sizeof(struct sensor_conductivity), "conductivity"},
{sizeof(struct sensor_energy), "energy"},
{sizeof(struct sensor_charge), "charge"},
+ {sizeof(struct sensor_inclinometer), "inclinometer"},
Review Comment:
move to first patch
--