Author: alg
Date: Thu Mar 20 14:36:21 2014
New Revision: 1579639
URL: http://svn.apache.org/r1579639
Log:
i124409 use slot SID_ATTR_METRIC to retrive the UI unit, not GetModuleFieldUnit
Modified:
openoffice/trunk/main/svx/source/sidebar/possize/PosSizePropertyPanel.cxx
Modified:
openoffice/trunk/main/svx/source/sidebar/possize/PosSizePropertyPanel.cxx
URL:
http://svn.apache.org/viewvc/openoffice/trunk/main/svx/source/sidebar/possize/PosSizePropertyPanel.cxx?rev=1579639&r1=1579638&r2=1579639&view=diff
==============================================================================
--- openoffice/trunk/main/svx/source/sidebar/possize/PosSizePropertyPanel.cxx
(original)
+++ openoffice/trunk/main/svx/source/sidebar/possize/PosSizePropertyPanel.cxx
Thu Mar 20 14:36:21 2014
@@ -91,7 +91,10 @@ PosSizePropertyPanel::PosSizePropertyPan
mlRotY(0),
maUIScale(),
mePoolUnit(),
- meDlgUnit(),
+
+ // #124409# init with fallback default
+ meDlgUnit(FUNIT_INCH),
+
maTransfPosXControl(SID_ATTR_TRANSFORM_POS_X, *pBindings, *this),
maTransfPosYControl(SID_ATTR_TRANSFORM_POS_Y, *pBindings, *this),
maTransfWidthControl(SID_ATTR_TRANSFORM_WIDTH, *pBindings, *this),
@@ -313,11 +316,15 @@ void PosSizePropertyPanel::Initialize()
}
mePoolUnit = maTransfWidthControl.GetCoreMetric();
- meDlgUnit = GetModuleFieldUnit();
- SetFieldUnit( *mpMtrPosX, meDlgUnit, true );
- SetFieldUnit( *mpMtrPosY, meDlgUnit, true );
- SetFieldUnit( *mpMtrWidth, meDlgUnit, true );
- SetFieldUnit( *mpMtrHeight, meDlgUnit, true );
+
+ // #124409# no need to do this, the mpBindings->Update( SID_ATTR_METRIC )
+ // call in the constructor will trigger MetricState and will get the
correct unit
+ //
+ // meDlgUnit = GetModuleFieldUnit();
+ // SetFieldUnit( *mpMtrPosX, meDlgUnit, true );
+ // SetFieldUnit( *mpMtrPosY, meDlgUnit, true );
+ // SetFieldUnit( *mpMtrWidth, meDlgUnit, true );
+ // SetFieldUnit( *mpMtrHeight, meDlgUnit, true );
}
@@ -784,7 +791,13 @@ void PosSizePropertyPanel::NotifyItemUpd
// Pool unit and dialog unit may have changed, make sure that we
// have the current values.
mePoolUnit = maTransfWidthControl.GetCoreMetric();
- meDlgUnit = GetModuleFieldUnit();
+
+ // #124409# do not change; GetModuleFieldUnit uses
SfxModule::GetCurrentFieldUnit()
+ // which uses GetActiveModule() and if no items are set there (which is
the case e.g.
+ // for writer), will just return the system fallback of FUNIT_INCH which
is wrong.
+ // Anyways, with multiple open views the static call GetActiveModule is
ambigious
+ //
+ // meDlgUnit = GetModuleFieldUnit();
switch (nSID)
{
@@ -1202,6 +1215,9 @@ void PosSizePropertyPanel::MetricState(
bool bWidthBlank = false;
bool bHeightBlank = false;
String sNull = String::CreateFromAscii("");
+
+ // #124409# use the given Item to get the correct UI unit and initialize it
+ // and the Fields using it
meDlgUnit = GetCurrentUnit(eState,pState);
if( mpMtrPosX->GetText() == sNull )