subbu107 commented on issue #5866: Flink event time based windowing functions 
not working with pulsar
URL: https://github.com/apache/pulsar/issues/5866#issuecomment-568838901
 
 
   Hi @yjshen , I did also try with default trigger, it still didn't work.
   
   Basically it can be simulated in the following way :
    - set flink env parallelism to 4 
    - set 
consumerConfigurationData.setSubscriptionType(SubscriptionType.Failover); .
    - number of partitions of source/ sink topics = 2
    - If I increase the number of partitions on  my source and sink topics to 
4, it works. Basically if I have fewer partitions than the parallelism that I 
have set in flink, it stops working.
    
    
    - when I set 
    consumerConfigurationData.setSubscriptionType(SubscriptionType.Shared);, it 
always works.
   However, since we want to maintain processing order, we want to use 
SubscriptionType.Failover
   
   
   I will attach the logs shortly

----------------------------------------------------------------