DanielLeens commented on issue #11739:
URL: https://github.com/apache/seatunnel/issues/11739#issuecomment-5239946418

   Thanks for opening this follow-up audit.
   
   I re-checked current `dev`, and the issue is real as a 
connector-by-connector bounded-read gap:
   
   - MySQL CDC now exposes `stop.mode` values `never`, `latest`, and `specific`.
   - Postgres, Oracle, SQL Server, and MongoDB still expose only `never` in 
their public `stop.mode` options today.
   
   So this is not just a documentation mismatch. The MySQL work has moved the 
capability forward, but the other `FetchTask`-based connectors still do not 
expose an end-to-end bounded-read contract yet.
   
   I would keep this issue as the audit / umbrella rather than turn it into one 
giant implementation PR.
   
   The next highest-value step is the matrix you outlined:
   - per connector, confirm the stop-offset ordering semantics are strong 
enough for comparison;
   - confirm where the streaming task can actually observe and enforce the stop 
boundary;
   - define the E2E proof that the job reaches `FINISHED` rather than just 
stopping emission while the reader keeps running.
   
   Once that is written down, follow-up PRs can stay one connector at a time 
instead of mixing Oracle / PostgreSQL / SQL Server / MongoDB semantics into one 
review.
   


-- 