hutiefang76 opened a new issue, #12507: URL: https://github.com/apache/seatunnel/issues/12507
### Description DuckDB JDBC Source silently wraps unsigned integer values outside the corresponding signed range. With DuckDB JDBC 1.3.1, a real JdbcSourceFactory run reads each of these as -1: | DuckDB type | Input | SeaTunnel output | | --- | --- | --- | | UTINYINT | 255 | -1 | | USMALLINT | 65535 | -1 | | UINTEGER | 4294967295 | -1 | | UBIGINT | 18446744073709551615 | -1 | The driver's getObject reads all four correctly. DuckDBTypeConverter currently maps them to BYTE, SHORT, INT and LONG respectively. The documented DuckDB source mapping instead lists SMALLINT, INT, BIGINT and DECIMAL(20,0). Existing Source/Sink tests use small unsigned values and miss the overflow. ### Reproduction Create a DuckDB table with these four column types and insert the values above. Read it with JDBC source using driver org.duckdb.DuckDBDriver and table_path main.<table>. The inferred schema narrows the values during ResultSet conversion. ### Expected behavior Preserve the complete unsigned range with wider inferred types. Signed integer mappings should remain unchanged. I have a focused fix and a regression covering upper boundaries, zero, null, and round trips into precreated and catalog-generated tables. -- This is an automated message from the Apache Git Service. To respond to the message, please log on to GitHub and use the URL above to go to the specific comment. To unsubscribe, e-mail: [email protected] For queries about this service, please contact Infrastructure at: [email protected]