DanielLeens commented on issue #12492: URL: https://github.com/apache/seatunnel/issues/12492#issuecomment-5869561721
Classification: A / Zeta WAL failure containment. The revised design withdraws the unsafe blanket Throwable catch and now draws the required boundary: fatal VM, thread, and linkage failures must first make the WAL path permanently unavailable and best-effort complete the affected request, then propagate to controlled node failure. No Error is approved as recoverable in v1, and a Disruptor handler must not turn such a failure into a silently resumed consumer. That is the right design direction, but it is not an implementation approval. #12081 remains open, BLOCKED, and Build-failed, so its Exception fail-close behavior is not a merged dev baseline. Do not start this dependent PR until that gate is green, merged, and rebased. Before coding, record the exact queued-versus-later APPEND contract and the rethrow boundary; use a safe synthetic Error regression, never a real OOM test. No label or assignment change in this pass. -- This is an automated message from the Apache Git Service. To respond to the message, please log on to GitHub and use the URL above to go to the specific comment. To unsubscribe, e-mail: [email protected] For queries about this service, please contact Infrastructure at: [email protected]