SEZ9 commented on issue #13477: URL: https://github.com/apache/seatunnel/issues/13477#issuecomment-7204369392
Thanks for the detailed report, with the CI links, timeline, reproduction numbers and thread dump. It is complete enough to act on, and thanks for offering to work on it. Based on your measurements, the direction you proposed sounds reasonable: have `SinkRegisterOperation` fail the registration at once when the committer task group has ended, keep retrying while it is not deployed yet, and switch `SinkFlowLifeCycle.registerCommitter()` to the interruptible `get()`. The planned `seatunnel-engine-server` test plus the existing `cancelJobTest` also sounds good. Please go ahead and open a PR. Your restore-path question is still open and I have not confirmed it here. Since the cleanup in `SubPlan.prepareRestorePipeline` is best effort, could you also add a test for the restore case in the PR, showing that a restored sink keeps retrying until the new committer is active? It would also help to describe in the PR what happens when that cleanup fails, so the behaviour can be reviewed there. <!-- streview-comment:2641 --> -- This is an automated message from the Apache Git Service. To respond to the message, please log on to GitHub and use the URL above to go to the specific comment. To unsubscribe, e-mail: [email protected] For queries about this service, please contact Infrastructure at: [email protected]