Hi David, Unfortunately there's really no way to do what you're hoping to do in an automatic way. You can move the block files (including their .meta files) from one disk to another. Do this when the datanode daemon is stopped. Then, when you start the datanode daemon, it will scan dfs.data.dir and be totally happy if blocks have moved hard drives. I've never tried to do this myself, but others on the list have suggested this technique for "balancing disks."
You could also change your process around a little. It's not too crazy to decommission an entire node, replace one of its disks, then bring it back into the cluster. Seems to me that this is a much saner approach: your ops team will tell you which disk needs replacing. You decommission the node, they replace the disk, you add the node back to the pool. Your call I guess, though. Hope this was helpful. Alex On Thu, Sep 10, 2009 at 6:30 PM, David B. Ritch <[email protected]>wrote: > What do you do with the data on a failing disk when you replace it? > > Our support person comes in occasionally, and often replaces several > disks when he does. These are disks that have not yet failed, but > firmware indicates that failure is imminent. We need to be able to > migrate our data off these disks before replacing them. If we were > replacing entire servers, we would decommission them - but we have 3 > data disks per server. If we were replacing one disk at a time, we > wouldn't worry about it (because of redundancy). We can decommission > the servers, but moving all the data off of all their disks is a waste. > > What's the best way to handle this? > > Thanks! > > David >