Hi, I'm experiencing some sigsegv when running some tests with a 3G modem. I have 2 active connections : - an ethernet link, configured with dhcp. Typical setup is ip = 10.23.218.30 mask = 255.255.240.0 gw = 10.23.208.1 - a 3G modem, configured with ofono. Typical setup is ip = 10.248.160.97 mask = 255.255.255.255 gw = 0.0.0.0
The sim card used is configured with a dedicated password authenticated APN connected to our internal network through vpn. So both links ends up on the same network, with different mask. This is a bogus network setup, and the values provided by the gsm operator looks strange but connman should not crash. I'm simulating gsm coverage loss with an antenna attenuator and connman crashes when the gsm signal is back or when calling ofono activate_context again. The decoded backtrace : -------- backtrace -------- [0]: update_order() [connection.c:466] [1]: __connman_profile_changed() [profile.c:182] [2]: __connman_service_indicate_state() [service.c:3046] [3]: set_configuration() [network.c:574] [4]: set_connected_fixed() [network.c:591] [5]: connman_network_set_connected() [network.c:812] [6]: signal_filter() [watch.c:403] [7]: message_filter() [watch.c:530] [8]: message_dispatch() [mainloop.c:80] [9]: main() [main.c:262] [10]: _start() [start.S:122] --------------------------- I can post the full syslog or run some other tests if needed. I'll try to reproduce the bug differently, it seems to be related to gateway management. -- Sincerly, Benoît. _______________________________________________ connman mailing list [email protected] http://lists.connman.net/listinfo/connman