https://bugs.contribs.org/show_bug.cgi?id=10514
Bug ID: 10514
Summary: update to backupPC 4
Classification: Contribs
Product: SME Contribs
Version: 9.2
Hardware: ---
OS: ---
Status: CONFIRMED
Severity: normal
Priority: P3
Component: smeserver-BackupPC
Assignee: [email protected]
Reporter: [email protected]
QA Contact: [email protected]
Target Milestone: ---
install the BackupPC4 (SME 9.X)
installfws repo
yum --enablerepo=smecontribs,fws install smeserver-BackupPC BackupPC4updates
configuration files following the installation
Dépendance(s) installée(s) :
BackupPC-XS.x86_64 0:0.57-1
perl-Archive-Zip.noarch 0:1.30-2.el6
perl-Class-Singleton.noarch 0:1.4-6.el6
perl-DateTime.x86_64 1:0.5300-3.el6
perl-DateTime-Format-Mail.noarch 0:0.3001-6.el6
perl-DateTime-Format-W3CDTF.noarch 0:0.04-8.el6
perl-Net-FTP-AutoReconnect.noarch 0:0.3-3.el6
perl-Net-FTP-RetrHandle.noarch 0:0.2-3.el6
perl-Params-Validate.x86_64 0:0.92-3.el6
perl-Time-modules.noarch 0:2006.0814-5.el6
perl-XML-RSS.noarch 0:1.45-2.el6
rsync-bpc.x86_64 0:3.0.9.11-1
smeserver-remoteuseraccess.noarch 0:1.3-2.el6.sme
Terminé !
then
signal-event backuppc-update
then conect to the manager ; left panel is ok, but main page will display :
Error: Unable to connect to BackupPC server
This CGI script (/BackupPC) is unable to connect to the BackupPC server on
localhost port -1.
The error was: unix connect: No such file or directory.
Perhaps the BackupPC server is not running or there is a configuration error.
Please report this to your Sys Admin.
message log shows:
Feb 9 15:03:11 atlas esmith::event[27815]: Processing event: backuppc-update
...
Feb 9 15:03:13 atlas esmith::event[27815]: adjusting non-supervised backuppc
(restart)
Feb 9 15:03:13 atlas esmith::event[27815]: Shutting down BackupPC:
#033[60G[#033[0;31mÉCHOUÉ#033[0;39m]#015
Feb 9 15:03:14 atlas esmith::event[27815]: Starting BackupPC: 2018-02-09
15:03:14 $Conf{PingPath} = '/usr/bin/ping' is not a valid executable program
Feb 9 15:03:14 atlas esmith::event[27815]:
#033[60G[#033[0;31mÉCHOUÉ#033[0;39m]#015
Feb 9 15:03:14 atlas esmith::event[27815]: serviceControl: Couldn't
system(/etc/rc.d/rc7.d/S98backuppc, restart):
Feb 9 15:03:14 atlas esmith::event[27815]: adjusting supervised httpd-e-smith
(sigusr1)
Feb 9 15:03:14 atlas esmith::event[27815]: adjusting supervised httpd-e-smith
(up)
Feb 9 15:03:14 atlas esmith::event[27815]: adjusting supervised httpd-bkpc
(sigusr1)
Feb 9 15:03:14 atlas esmith::event[27815]: adjusting supervised httpd-bkpc
(up)
Feb 9 15:03:14 atlas esmith::event[27815]:
adjust-services=action|Event|backuppc-update|Action|adjust-services|Start|1518206593
394499|End|1518206594 41029|Elapsed|0.64653
editing the file /etc/BackupPC/config.pl at line 1588
$Conf{PingPath} = "/bin/ping";
to
$Conf{PingPath} = "/usr/bin/ping";
fixes this
# /etc/init.d/backuppc start
Starting BackupPC: [ OK ]
--
You are receiving this mail because:
You are the QA Contact for the bug._______________________________________________