Hi paul,
Kevin did write to me asking if  I could submit a detailed bug report.

Strangely, I could not reproduce the problem.  I am still running revision
1950 ..On that day myself and one other person ( I think it was Dr Eleanor
Dodson) reported that the rigid body fit zone ..was stopping  after the
first click.

I  have since used rigid body fit zone many times without any problem in rev
1950

I had two more unrelated issues.
# Add terminal residue and simultaneous movement
Didnt coot previously also allow you to simultaneously rotate-translate a
terminal atom concurrently with the addition.

Now in revision 1947 onwards. Clicking add terminal residue only allows you
to move the atom around using the mouse . So all end residue additions are
two steps , first add, then accept and then again rotate translate zone to
position. Is this intended.


# Copy_from_ncs_master_to_others : creates all atoms as stars in ncs mates


Thanks
hari

On Thu, Apr 23, 2009 at 4:34 PM, Paul Emsley <[email protected]>wrote:

> hari jayaram wrote:
>
>> Hello ,
>>
>> I just noticed that rigid body fit zone in revision 1950 stops expecting
>> user mouse clicks after clicking on the first atom .
>>
>> Is anyone else seeing this.
>>
>>
>>
> Hi Hari,
>
> Do you mean rigid body fit or Rotate/Translate mode?  (Rotate/Translate can
> go into "single click mode" (it's designed to)).
>
> I can't reproduce the problem of rigid body fit going into "single click
> mode"
>
> Paul.
>

Reply via email to