Paul Emsley wrote:
Dear Oliver,

Antony Oliver wrote:
Dear Paul + friends,

Would it be possible to place in the (top right?) corner of the main screen (or elsewhere) an indicator telling the user what type of restraints are currently being used for real- space refinement/fitting? I frequently forget that I have put alpha helix restraints on when building, and wonder why my amino acids are drifting so dramatically out of my electron density!
We were talking about this problem just recently (at the CCP4 dev meeting, I think). Yes an iconic indicator would be nice. What would be more clever, we think (or at least I think we think) is for Coot to realise that helical (or strand) restraints are active and examine the "helicalness" ("strandiness") of the fragment that you are trying to refine - and if it passes a threshold of sufficient difference from ideality then you get a warning - something along the lines of an "Are you sure?" dialog.

Great- although I have to say "Are you sure?" dialogs are an evil that should be avoided - they drive me mad! (the Undo is sufficient!)


I think it would also be useful if something similar could also be displayed to indicate which map you are using for fitting and refinement - I often have 2fo-fc maps, fo-fc maps, and ncs-averaged maps loaded - and often have to switch between them when building - and frequently forget which one I am currently using.

Yes, OK.  For 0.7.

Fantastic.


And, speaking of NCS.... I would really appreciate a script that could superimpose a selected molecule onto all the ncs-related molecules and write them all out to a PDB. I currently do it manually, by SSM Superpose, change chain ID, and writing out to PDB. Which is fine when you only have two or three molecules in the asymmetric unit, but when you have more...

The copy-chain function is supposed to do something very like that. If by "selected molecule" you mean Coot's NCS master chain, then copy-chain is what you want (Extensions -> NCS -> Copy NCS chain...). If the "selected molecule" is not part of NCS molecule, you will have to do a bit of massaging.

Paul.
Mea culpa - that worked beautifully. However, it didn't work all that well at the start of my model building, presumably because the sequence identity between molecules was low (lots of polyalanine)....

Many thanks.

Tony.




The Institute of Cancer Research: Royal Cancer Hospital, a charitable Company 
Limited by Guarantee, Registered in England under Company No. 534147 with its 
Registered Office at 123 Old Brompton Road, London SW7 3RP.

This e-mail message is confidential and for use by the addressee only.  If the 
message is received by anyone other than the addressee, please return the 
message to the sender by replying to it and then delete the message from your 
computer and network.
begin:vcard
fn:Antony Oliver
n:Oliver;Antony
org:The Institute of Cancer Research;Section of Structural Biology
adr:Chelsea;;237 Fulham Road;LONDON;;SW3 6JB;England
email;internet:[email protected]
title:Dr Antony W Oliver
tel;work:020 7153 5451 / 5571
tel;fax:020 7153 5457
x-mozilla-html:TRUE
url:http://www.icr.ac.uk/structbi
version:2.1
end:vcard

Reply via email to