On 5/14/10 7:57 PM, Nils wrote: > Op vrijdag 14 mei 2010 13:13:39 schreef u: > >> This patch should fix the hda interrupt lost problem on the Wyse S50 >> >> > Hi Stefan, > Thanks for making this patch. :) > Unfortunately i have no time today to test it, maybe tomorrow evening. > I quickly browsed the code, am i correct that you disabled the CS5536 > code for GX2 ? > You are aware of the fact that the wyse s50 has a CS5536? (i think the Rumba > and olpc`s also) > Hi Nils,
until a while back the GX2 code contained code to set up the CS5535 and the CS5536. The CS5536 code under src/southbridge contained a different version of that code. But gcc chose to use the code under src/southbridge. Because that choice was rather arbitrary we cleaned up the GX2 code a while back to not call the src/southbridge init code but the version in src/northbridge, so it would work with the same code path of CS5535 and CS5536. However, the CS5536 code in src/northbridge is no good and so moved all CS5535/CS5536 code out of the GX2. The CS5535 code was moved to src/southbridge/CS5535, while the CS5536 code already contains a (working) version of that code that was previously living in the GX2 component. So, what I did is move CS5535 code to the CS5535 directory and make sure there is no southbridge code in the northbridge directory because it really does not belong there. Stefan -- coreboot mailing list: [email protected] http://www.coreboot.org/mailman/listinfo/coreboot