On Mar 8, 8:29am, Tom Ivar Helbekkmo wrote:
} John Nemeth <[email protected]> writes:
}
} > The 2924 is an old switch so it may behave funny.
}
} Yeah, the most common problem with these old Ciscos is that the
} autoconfiguration randomly fails -- sometimes after having worked well
} again and again for a long time.
}
} > Could you set both ends to auto/auto and see what happens?
}
} In this case, they managed to both decide on 100/full -- and
} communication fails in the same way.
This tells us that the hardware is fundamentally sound, i.e.
it is receiving data and acting on it. That tends to indicate that
it is a driver issue. msaitoh@ is our driver expert, so I'm going
to bow out.
}-- End of excerpt from Tom Ivar Helbekkmo