Hi all, I encounter the same problem.
However, the Alt-Gr key works when I am using Exceed to log in. Therefore I do not belief its a problem with the HP machine. The Alt-Gr key also works in the cygwin bash for me. Regards Franz > Hi, > > Using startxwin.bat and xev, gives me the following: > > KeyPress event, serial 22, synthetic NO, window 0x800001, > root 0x3a, subw 0x0, time 25294468, (167,-13), root:(627,587), > state 0x10, keycode 113 (keysym 0xfe03, ISO_Level3_Shift), same_screen > YES, XLookupString gives 0 characters: "" > > KeyPress event, serial 22, synthetic NO, window 0x800001, > root 0x3a, subw 0x0, time 25294531, (167,-13), root:(627,587), > state 0x90, keycode 113 (keysym 0xfe03, ISO_Level3_Shift), same_screen > YES, XLookupString gives 0 characters: "" > > and AltGr is working well on this one. > > Unfortunately I don't have xev running on the HP-UX box... > > Not only CDE has the behaviour of not using AltGr, but another > X-application I use as well. > > Hope it helps. > > Regards, Hans. > > Alexander Gottwald escribi�: > > On Thu, 6 Nov 2003, Hans Dekker wrote: > > > Hi Takuma, > > I tried Xterm and there is works OK. As I read the documentation > on the usage of xdmcp to start a CDE environment, changing the > XF86Config should be working, however I didn't find how to do it > in the case of a Spanish keyboard. > > What is the auto detection option you are talking about? > > > > The autodetection changes the layout according to the layout used in > windows. This can be overridden in the XF86Config file but this not > needed in most cases. > > > If the layout is correct with startxwin.bat then it is also loaded with > xdmcp. Maybe CDE does load a wrong modmap? > > > Can you try xev and press Alt-Gr? > > For me it reports the following. > > KeyPress event, serial 22, synthetic NO, window 0x1600001, > root 0x3a, subw 0x1600002, time 1891239428, (55,39), root:(136,215), > state 0x0, keycode 113 (keysym 0xfe03, ISO_Level3_Shift), same_screen > YES, XLookupString gives 0 characters: "" > > > KeyRelease event, serial 27, synthetic NO, window 0x1600001, > root 0x3a, subw 0x1600002, time 1891239498, (55,39), root:(136,215), > state 0x80, keycode 113 (keysym 0xfe03, ISO_Level3_Shift), same_screen > YES, XLookupString gives 0 characters: "" > > > bye > ago > ------------------------------- Dr. Franz Roters Max-Planck-Institut fuer Eisenforschung Abteilung Mikrostrukturphysik und Umformtechnik Max-Planck-Str. 1 40237 Duesseldorf Germany Tel.: +49 (0)211-6792-393 FAX: +49 (0)211-6792-333
