Hello Johannes,

EMIFA and ATA are multiplexed modules. You cannot access both
simultaneously. This is clearly documented in the EMIFA and ATA/CF pin
terminal function tables. Please refer to Section 3.6.6.4 of
TMS320DM6446 Datasheet.

Regards,
Satheesh S

**********************************************************************