On 12/1/06, Arnaldo Carvalho de Melo <[EMAIL PROTECTED]> wrote:
> Can I suggest that people test CCID3 on a range of loss, rtt
> combinations please? CCID3 has proven time after time to be very
> sensitive....
As I told you, I'm preparing a more comprehensive test environment
here, just being sidetracked by some problems using net-2.6.20 on a
parisc64 machine.
- Arnaldo
Yes you did say that which is good. I will try and document my test
procedures on OSDL Wiki at some stage. Basically I just use netem on
Linux router though and compare performance to
http://wand.net.nz/~perry/max_download.php (remember to set MSS to
packet size used in iperf) - results within about 20% are normal.
Local machines I get 80+Mbits (on 100 Mbits card) and 30-40 Mbits on
machine through router.
If you get a funny test result then rerun as random netem loss can
cause random results at times. I usually run iperf for 10-20 seconds
(10 is the default)
Ian
--
Web: http://wand.net.nz/~iam4
Blog: http://imcdnzl.blogspot.com
WAND Network Research Group
-
To unsubscribe from this list: send the line "unsubscribe dccp" in
the body of a message to [EMAIL PROTECTED]
More majordomo info at http://vger.kernel.org/majordomo-info.html