|  The idea is to start the timer when DCCP is loaded. This gives
|  2^32-1 usecs = circa 49 days before the clock wraps around.
Oops, it is not milliseconds but microseconds ... that means the counter
wraps around every 71 seconds. If the maximum RTT is 3 seconds, then this
means wrap-around every 20 RTTs.

Maybe this is too much?
-
To unsubscribe from this list: send the line "unsubscribe dccp" in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html