Dear dealers,

   I've faced the following problem.

   As a test example I have a program which solves nondimensional heat
   equation using forward Euler method in time. The time step is
   chosen appropriately that solution does not blow up (CFL
   condition it is called?) dt = 0.4e-4.
   There are no hanging nodes, mesh is constant.

   Then I modified this code (following tutorial 17) to run it in
   parallel using PETSC (just as a sand-box be sure that I understood
   how the parallel tools work). Principally nothing have changed
   except CG solver (for "inversion" of the mass matrix) now is used from PETSC
   and it uses another preconditioner. Problem - in this case after
   around 10 time steps solution blows up with the same time step used
   before (dt = 0.4e-4)! During these first successful steps norm of
   the solution for parallel version and for serial coincide up to 5
   digits, but after some time in parallel version it blows up. This
   happens both running the code with 2 or 1 processors. Furthermore
   if I will set time step 1 order of magnitude smaller (dt = 0.4e-5)
   then everything will work fine. If take dt = 0.3,0.2,0.1 e-4
   solution will fail.

   Could anybody provide explanation for that? Of course if needed I
   can provide both codes, they are simple.

Regards,
Slawa

_______________________________________________
dealii mailing list http://poisson.dealii.org/mailman/listinfo/dealii

Reply via email to