On Thu, Feb 26, 2009 at 03:38:49PM -0500, Lennart Sorensen wrote:
> On Thu, Feb 26, 2009 at 11:41:03AM +1100, Alex Samad wrote:
> You get nice hotswap bay LED control to show which drive has failed
> (I imagine software could do this too, but I have never seen that
> happen yet.)
Since the status of each physical drive is included in the
/proc/megaraid/* then software that monitors the appropriate files will
be able to tell you. This is one of the requirements for the software
I'm designing. It will note when a drive isn't optimal and {syslog |
email | wall | whatever}.
Doug.
--
To UNSUBSCRIBE, email to [email protected]
with a subject of "unsubscribe". Trouble? Contact [email protected]