On Sun, Feb 16, 2020 at 01:33:55PM +0100, Christian Kastner wrote: > On armel, dividing a flow by zero does not raise an exception, as it > does on other platforms. >... > Any suggestions on how to deal with this? Is this really a bug, or is my > test program above missing something? >...
armel is the only current release architecture without an FPU in the port baseline. The FPU emulation is known to not be 100% correct, so even though this specific issue does not sound familiar to me it is not a surprise. For software that is actually used on armel it is good enough that noone notices. For scientific software that relies on 100% correct floating point semantics it can be best to not ship it on armel, see #838496 for an example. cu Adrian