Your message dated Sat, 15 Feb 2014 11:02:43 +0100
with message-id 
<cagnkunfzpvukxmqmh9o9b2-o5_pj9h2+4wu2imufizcuhu8...@mail.gmail.com>
and subject line read-edid: returns bogus mode data for S3 86C775/86C785 paired 
with an ADI MicroScan 5v
has caused the Debian Bug report #157931,
regarding read-edid: returns bogus mode data for S3 86C775/86C785 paired with 
an ADI MicroScan 5v
to be marked as done.

This means that you claim that the problem has been dealt with.
If this is not the case it is now your responsibility to reopen the
Bug report if necessary, and/or fix the problem forthwith.

(NB: If you are a system administrator and have no idea what this
message is talking about, this may indicate a serious mail system
misconfiguration somewhere. Please contact [email protected]
immediately.)


-- 
157931: http://bugs.debian.org/cgi-bin/bugreport.cgi?bug=157931
Debian Bug Tracking System
Contact [email protected] with problems
--- Begin Message ---
Package: read-edid
Version: 1.4.1-1
Severity: normal

The card it reports is correct; it gives bogus X settings though.  The
monitor is an ADI MicroScan 5v (lm-1764):

<URL:http://www.griffintechnology.com/monitors/ADI20.html>


get-edid: get-edid version 1.4.1

        Performing real mode VBE call
        Interrupt 0x10 ax=0x4f00 bx=0x0 cx=0x0
        Function supported
        Call successful

        VBE version 200
        VBE string at 0xc0df0 "S3 Incorporated. 86C775/86C785"

VBE/DDC service about to be called
        Report DDC capabilities

        Performing real mode VBE call
        Interrupt 0x10 ax=0x4f15 bx=0x0 cx=0x0
        Function supported
        Call successful

        Monitor and video card combination does not support DDC1 transfers
        Monitor and video card combination supports DDC2 transfers
        0 seconds per 128 byte EDID block transfer
        Screen is not blanked during DDC transfer

Reading next EDID block

VBE/DDC service about to be called
        Read EDID

        Performing real mode VBE call
        Interrupt 0x10 ax=0x4f15 bx=0x1 cx=0x0
        Function supported
        Call successful

ÿÿÿÿÿÿ‰¼0}h’ 
WO—&HOÿþ€¾
        # EDID version 1 revision 0

Section "Monitor"
        Identifier "ADI:010b"
        VendorName "ADI"
        ModelName "ADI:010b"
        # DPMS capabilities: Active off:yes  Suspend:yes  Standby:no

        Mode    "1x1"   # vfreq 38.609Hz, hfreq  9.961kHz
                DotClock        2.570000
                HTimings        1 2 3 258
                VTimings        1 1 18 258
        EndMode
        Mode    "1x1"   # vfreq 38.609Hz, hfreq  9.961kHz
                DotClock        2.570000
                HTimings        1 2 3 258
                VTimings        1 1 18 258
        EndMode
        Mode    "1x1"   # vfreq 38.609Hz, hfreq  9.961kHz
                DotClock        2.570000
                HTimings        1 2 3 258
                VTimings        1 1 18 258
        EndMode
        Mode    "1x1"   # vfreq 38.609Hz, hfreq  9.961kHz
                DotClock        2.570000
                HTimings        1 2 3 258
                VTimings        1 1 18 258
        EndMode
EndSection



--- End Message ---
--- Begin Message ---
This bug is not longer present in 3.X branch, due to the new I2C
interface, please update.

-- 
Pozdrawiam,
Dariusz Dwornikowski, Assistant
Institute of Computing Science, Poznań University of Technology
www.cs.put.poznan.pl/ddwornikowski/
room 2.7.2 BTiCW | tel. +48 61 665 29 41

--- End Message ---

Reply via email to