On 12/17/2014 01:29 AM, John Paul Adrian Glaubitz wrote:
> This particular scanner is notorious to have issues when the warmup
> period is set to "-1" which means "auto". Try setting this to "0"
> (no warmup) and see if that fixes your issue.

Oh, and this setting is to be found in /etc/sane.d/plustek.conf.

Adrian

-- 
 .''`.  John Paul Adrian Glaubitz
: :' :  Debian Developer - glaub...@debian.org
`. `'   Freie Universitaet Berlin - glaub...@physik.fu-berlin.de
  `-    GPG: 62FF 8A75 84E0 2956 9546  0006 7426 3B37 F5B5 F913


-- 
To UNSUBSCRIBE, email to debian-bugs-dist-requ...@lists.debian.org
with a subject of "unsubscribe". Trouble? Contact listmas...@lists.debian.org

Reply via email to