Package: smartmontools
Version: 5.33+5.34cvs20050802-4
Severity: normal

smartd reports incorrect temperatures for an EIDE hard drive:

    $ egrep "hda.*194" /var/log/daemon.log | tail -1
    Apr  8 19:36:12 billchase smartd[6495]: Device: /dev/hda, SMART Usage 
Attribute: 194 Temperature_Celsius changed from 157 to 161 

However, hddtemp is able to report a more reasonable value:

    $ hddtemp /dev/hda
    /dev/hda: HDS722525VLAT80: 34 C

According to smartctl, this appears to be the 'RAW_VALUE', while smartd
is reporting the 'VALUE':

=== START OF INFORMATION SECTION ===
Model Family:     Hitachi Deskstar 7K250 series
Device Model:     HDS722525VLAT80
Serial Number:    VNR9HEC6C6YBUL
Firmware Version: V36OA60A
User Capacity:    250,059,350,016 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   6
ATA Standard is:  ATA/ATAPI-6 T13 1410D revision 3a
Local Time is:    Sat Apr  8 19:47:00 2006 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

[...]

ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
[...]
194 Temperature_Celsius     0x0002   161   161   000    Old_age   Always       
-       34 (Lifetime Min/Max 18/55)

-- Package-specific info:
Ouput of /usr/share/bug/smartmontools:
# CONFIG_IDE_TASK_IOCTL is not set

-- System Information:
Debian Release: testing/unstable
  APT prefers unstable
  APT policy: (990, 'unstable'), (1, 'experimental')
Architecture: i386 (i686)
Shell:  /bin/sh linked to /bin/bash
Kernel: Linux 2.6.16-1-k7-smp
Locale: LANG=C, LC_CTYPE=C (charmap=ANSI_X3.4-1968)

Versions of packages smartmontools depends on:
ii  libc6                         2.3.6-5    GNU C Library: Shared libraries an

Versions of packages smartmontools recommends:
ii  mailx            1:8.1.2-0.20050715cvs-1 A simple mail user agent

-- no debconf information

-- 