Package: sensord
Version: 1:2.9.1-1
Severity: normal
I've been receiving the following alarm message on a Tyan S2495 KT400.
I've set in0_min and in0_max for a 1.7V core (rather than a 1.8V
default) and I've made the other KT400 changes as suggested in
/etc/sensors.conf. I don't know why this flags the VCore out of range
when the alarm message shows a VCore that is in range.
May 20 14:52:08 johnson sensord: Sensor alarm: Chip w83697hf-isa-0290:
VCore: +1.71 V (min = +1.62 V, max = +1.78 V) [ALARM]
-- System Information:
Debian Release: 3.1
APT prefers testing
APT policy: (500, 'testing'), (50, 'unstable')
Architecture: i386 (i686)
Kernel: Linux 2.6.8-2-k7
Locale: LANG=en_US, LC_CTYPE=en_US (charmap=ISO-8859-1)
Versions of packages sensord depends on:
ii libc6 2.3.2.ds1-21 GNU C Library: Shared libraries an
ii librrd0 1.0.49-1 Time-series data storage and displ
ii libsensors3 1:2.9.1-1 library to read temperature/voltag
ii lm-sensors 1:2.9.1-1 utilities to read temperature/volt
-- no debconf information
--