Julien PUYDT <[email protected]> wrote: Hi,
> I can still find the scanner on the server (the box it is connected > to, newton), but not from the network anymore. When I try to run > "saned -d" and connect with telnet from a client, then I get : Bug confirmed, this is linked to the switch to bindv6only=1 by default. Until it's fixed, you can work around it by doing echo 0 > /proc/sys/net/ipv6/bindv6only before starting saned. You can also edit /etc/sysctl.d/bindv6only.conf and set the value to 0 if you want the change to be permanent. JB. -- Julien BLACHE - Debian & GNU/Linux Developer - <[email protected]> Public key available on <http://www.jblache.org> - KeyID: F5D6 5169 GPG Fingerprint : 935A 79F1 C8B3 3521 FD62 7CC7 CD61 4FD7 F5D6 5169 -- To UNSUBSCRIBE, email to [email protected] with a subject of "unsubscribe". Trouble? Contact [email protected]