On Thursday 22 Jul 2010 04:53:00 Russell Ault wrote:
> Sorry it has taken me so long to reply. I believe I am using ifup scripts
> (neither network-manager or wicd are installed on the machine). I am using
> what is the default on a business card i386 installation.
> 
> Apparently the problem is slightly intermittent. I rebooted the server so I
> could generate a boot log, only to discover that iSCSI came up properly
> the first time. It didn't the second time. Here's a dump of
> /var/log/messages:

No, I need the boot.log file. Enable boot logging in /etc/default/bootlogd and 
then once logged, please post /var/log/boot

Being intermittent could also be because it might be more of a timing related 
bug (highly dependent on how fast an ethernet link gets initialized)



-- 
Ritesh Raj Sarraf
RESEARCHUT - http://www.researchut.com
"Necessity is the mother of invention."

Attachment: signature.asc
Description: This is a digitally signed message part.

Reply via email to