Package: libsane1 Version: 1.0.32-4 Severity: grave Justification: renders package unusable
Dear Maintainer, I've upgraded libsane1 package from 1.0.31-4.1 to 1.0.32-4 and my Epson Perfection 164SU stopped working. I tried to debug the issue with: ~$ SANE_DEBUG_EPSON2=255 scanimage --device=epson2:libusb:006:011 --format=jpeg --output-file=./test.jpg and I discoverd this error: ... [00:15:42.111491] [epson2] setting focus failed scanimage: sane_start: Operation not supported ... I think that this error is related to this changelog of "SANE Backends 1.0.32": epson2: adds autofocus support for devices that support it (!531) Info: https://gitlab.com/sane-project/backends/-/merge_requests/531 https://gitlab.com/sane-project/backends/-/merge_requests/531/diffs Downgrading to libsane1 1.0.31-4.1 solve the issue. -- System Information: Debian Release: bookworm/sid APT prefers testing APT policy: (850, 'testing') Architecture: amd64 (x86_64) Kernel: Linux 5.14.0-2-amd64 (SMP w/8 CPU threads) Kernel taint flags: TAINT_OOT_MODULE, TAINT_UNSIGNED_MODULE Locale: LANG=it_IT.UTF-8, LC_CTYPE=it_IT.UTF-8 (charmap=UTF-8), LANGUAGE=en_US Shell: /bin/sh linked to /bin/dash Init: systemd (via /run/systemd/system) LSM: AppArmor: enabled Versions of packages libsane1 depends on: ii acl 2.3.1-1 ii adduser 3.118 ii libavahi-client3 0.8-5 ii libavahi-common3 0.8-5 ii libc6 2.32-4 ii libcairo2 1.16.0-5 ii libcurl3-gnutls 7.74.0-1.3+b1 ii libgcc-s1 11.2.0-10 ii libglib2.0-0 2.70.0-3 ii libgphoto2-6 2.5.27-1 ii libgphoto2-port12 2.5.27-1 ii libieee1284-3 0.2.11-14 ii libjpeg62-turbo 1:2.0.6-4 ii libpng16-16 1.6.37-3 ii libpoppler-glib8 20.09.0-3.1 ii libsane-common 1.0.32-4 ii libsnmp40 5.9.1+dfsg-1 ii libstdc++6 11.2.0-10 ii libtiff5 4.3.0-2 ii libusb-1.0-0 2:1.0.24-3 ii libxml2 2.9.12+dfsg-5 ii udev 249.5-1 Versions of packages libsane1 recommends: ii ipp-usb 0.9.19-2 ii sane-utils 1.0.32-4 Versions of packages libsane1 suggests: ii avahi-daemon 0.8-5 pn hplip <none> -- no debconf information