Dear Mantainers, after the last kernel update (Debian Sid, v. 3.2.20-1) fancontrol works randomly.
The problem depends on the fact that the hwmon sensor alternates, at every boot, his path between /sys/devices/platform/eeepc/hwmon/hwmon1 and /sys/devices/platform/eeepc/hwmon/hwmon2. The only solution would be to reconfigure the fancontrol every time, but it is clear that this solution is extremely annoying. Here is my current /etc/fancontrol: # Configuration file generated by pwmconfig, changes will be lost INTERVAL=10 DEVPATH=hwmon0= hwmon2=devices/platform/eeepc DEVNAME=hwmon0=acpitz hwmon2=eeepc FCTEMPS=hwmon2/pwm1=hwmon0/temp1_input FCFANS= hwmon2/pwm1=hwmon2/fan1_input MINTEMP=hwmon2/pwm1=54 MAXTEMP=hwmon2/pwm1=70 MINSTART=hwmon2/pwm1=150 MINSTOP=hwmon2/pwm1=20 This does not work now because, after last boot, the sensor has been recognized as hwmon1. I hope I was clear and I apologize for my bad English Hi and thank you very much, Domenico
_______________________________________________ Debian-eeepc-devel mailing list [email protected] http://lists.alioth.debian.org/cgi-bin/mailman/listinfo/debian-eeepc-devel