21 октября 2009 г. 8:34 пользователь DamirX <[email protected]>написал:
> В Втр, 20/10/2009 в 17:36 +0400, Andrey Melnikoff пишет: > > После ICRC UNC IDNF (ошибка CRC, невосстановимая ошибка, адресный маркер > не найден) > > вывод smartctl -a /dev/sda в президиум. > > > > > # smartctl -a /dev/sda > smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen > Home page is http://smartmontools.sourceforge.net/ > > === START OF INFORMATION SECTION === > Model Family: Western Digital Caviar Second Generation Serial ATA > family > Device Model: WDC WD7500AAKS-00RBA0 > Serial Number: WD-WCAPT0585317 > Firmware Version: 30.04G30 > User Capacity: 750 156 374 016 bytes > Device is: In smartctl database [for details use: -P show] > ATA Version is: 7 > ATA Standard is: Exact ATA specification draft version not indicated > Local Time is: Wed Oct 21 08:00:56 2009 MSD > SMART support is: Available - device has SMART capability. > SMART support is: Enabled > > === START OF READ SMART DATA SECTION === > SMART overall-health self-assessment test result: PASSED > > General SMART Values: > Offline data collection status: (0x84) Offline data collection activity > was suspended by an interrupting > command from host. > Auto Offline Data Collection: > Enabled. > Self-test execution status: ( 0) The previous self-test routine > completed > without error or no self-test has > ever > been run. > Total time to complete Offline > data collection: (16800) seconds. > Offline data collection > capabilities: (0x7b) SMART execute Offline immediate. > Auto Offline data collection on/off > support. > Suspend Offline collection upon new > command. > Offline surface scan supported. > Self-test supported. > Conveyance Self-test supported. > Selective Self-test supported. > SMART capabilities: (0x0003) Saves SMART data before entering > power-saving mode. > Supports SMART auto save timer. > Error logging capability: (0x01) Error logging supported. > General Purpose Logging supported. > Short self-test routine > recommended polling time: ( 2) minutes. > Extended self-test routine > recommended polling time: ( 207) minutes. > Conveyance self-test routine > recommended polling time: ( 6) minutes. > SCT capabilities: (0x303f) SCT Status supported. > SCT Feature Control supported. > SCT Data Table supported. > > SMART Attributes Data Structure revision number: 16 > Vendor Specific SMART Attributes with Thresholds: > ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED > WHEN_FAILED RAW_VALUE > 1 Raw_Read_Error_Rate 0x000f 200 200 051 Pre-fail Always > - 0 > 3 Spin_Up_Time 0x0003 253 180 021 Pre-fail Always > - 1433 > 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always > - 76 > 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always > - 0 > 7 Seek_Error_Rate 0x000e 200 200 051 Old_age Always > - 0 > 9 Power_On_Hours 0x0032 082 082 000 Old_age Always > - 13151 > 10 Spin_Retry_Count 0x0012 100 253 051 Old_age Always > - 0 > 11 Calibration_Retry_Count 0x0012 100 253 051 Old_age Always > - 0 > 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always > - 76 > 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always > - 73 > 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always > - 76 > 194 Temperature_Celsius 0x0022 108 090 000 Old_age Always > - 44 > 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always > - 0 > 197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always > - 0 > 198 Offline_Uncorrectable 0x0010 200 200 000 Old_age Offline > - 0 > 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always > - 0 > 200 Multi_Zone_Error_Rate 0x0008 200 200 051 Old_age Offline > - 0 > > SMART Error Log Version: 1 > No Errors Logged > > SMART Self-test log structure revision number 1 > No self-tests have been logged. [To run self-tests, use: smartctl -t] > > > SMART Selective self-test log data structure revision number 1 > SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS > 1 0 0 Not_testing > 2 0 0 Not_testing > 3 0 0 Not_testing > 4 0 0 Not_testing > 5 0 0 Not_testing > Selective self-test flags (0x0): > After scanning selected spans, do NOT read-scan remainder of disk. > If Selective self-test is pending on power-up, resume after 0 minute delay. > > -- > DamirX > > > -- > To UNSUBSCRIBE, email to [email protected] > with a subject of "unsubscribe". Trouble? Contact > [email protected] > > > SMART Error Log Version: 1 > No Errors Logged По идее с винтом все нормально. -- With best regards, Vladislav Prokofyev