On Thu, Oct 29, 1998 at 10:36:16PM -0800, Jeffrey Ebert wrote: > I have a headless Sparc2, and I have succeeded in getting Debian running > on it. My problem is that the silo doesn't want to boot automatically. > It just sits there forever waiting for me to press the enter key. I > don't want to open the serial console every time I turn it on. I have > set the timeout to 0, removed the timeout line, tried various things > with the default= line, but nothing has worked. Any ideas?
I'm going to upload this week-end, a new silo package. I'm using silo 0.8.1 and timeout works on my SS2. ciao -- [EMAIL PROTECTED] (PROSA srl) - [EMAIL PROTECTED] (Sparc Debian) PGP fingerprint = CD 8D A9 1E DB 0C B0 16 F8 2F BF 63 52 49 8B A8