In article <[EMAIL PROTECTED]>,
Falk Hueffner  <[EMAIL PROTECTED]> wrote:
>[EMAIL PROTECTED] (Miquel van Smoorenburg) writes:
>> 
>> I've uploaded a fixed package to master for i386.
>
>Does the new version check if the running version of init is capable
>of correctly restarting init, or will I have to hope to be able to
>reboot fast enough?

It checks if the old version is >= 2.74 for i386, and >= 2.76
for all other architectures such as alpha.

Now if you install the new init _twice_ without rebooting in between
init will think it's being upgraded from 2.76-1 to 2.76-1 and
happily do an "init u" while 2.75-4 is still running .. so don't
do that :)

Mike.
-- 
... one of the main causes of the fall of the Roman Empire was that, lacking 
zero, they had no way to indicate successful termination of their C programs. 