Mandi! Philippe Troin In chel di` si favelave... > 1. When the machine is at runlevel 2, I can start minicom, login via > the serial console. If I close minicom without logging off, my > session stays pending there, waiting for the next person to run > minicom.
Sorry, i've no answer to this... > 2. Sometimes, the machine will go back to the OpenPROM prompt > without any reasonable cause. This happens whether or nor minicom > is attached to the serial console... If minicom is attached, I > can see the following output: ...but for this... i've a PC attached via serial line to a SS10, and also my SS10 hangs (i found now and then the ``ok'' prom prompt). Simply i've noticed that halt/boot my PC with serial connected send in some way a BREAK signal to serial line, and BREAK in serial console language are interpreted as Stop-A. Now i live with serial cable disconnected, i plug these only if needed and my SS10 have month of uptime... ;))) -- dott. ing. Marco Gaiarin Associazione ``La Nostra Famiglia'' http://www.lanostrafamiglia.it/ Polo FVG - Via della Bontà , 7 - 33078 - San Vito al Tagliamento (PN) gaio(at)sv.lnf.it tel +39-0434-842711 fax +39-0434-842797 No alla censura del Web: http://punto-informatico.it/petizione.asp