Carsten Dirk wrote:
[...]
> Probleme faxe versenden woran liegt das? Ich benutze Hylafax 4.1.1 unter woody
> mit einem US Robotics Modem Sporster Flash an ttyS0 angs.
> 
> 
> An attempt to receive facsimile on ttyS0 failed because:
> 
>     RSPREC invalid response received
> 
>     ---- Transcript of session follows ----

[...]
> Apr 27 14:03:55.82: [ 1952]: RECV: 197 total lines, 2 bad lines, 1 consecutive bad 
>lines
> Apr 27 14:03:55.82: [ 1952]: --> [16:+FPS:1,198,0,0,0]
> Apr 27 14:04:05.16: [ 1952]: --> [7:+FHS:A1]
> Apr 27 14:04:05.16: [ 1952]: REMOTE HANGUP: RSPREC invalid response received (code 
>A1)
> Apr 27 14:04:05.29: [ 1952]: --> [2:OK]
[...]

Da steht's woran es liegt...
und dann ist Google Dein Freund ;)

   A0...  |  RECEIVE PHASE D HANGUP CODES  (Class 2.0)      |
        +----------+-------------------------------------------------+
        |     A0   |  Unspecified Receive Phase D errors             |
        |     A1*  |  RSPREC invalid response received               |
        |     A2*  |  COMREC invalid response received               |
        |     A3   |  Unable to continue after PIN or PIP            |
        +----------+-------------------------------------------------+

        There are several possible causes for errors marked * in the table:
          1) excessively noisy phone line which disrupts communications;
          2) (in the case of transmission) far-end fax machine has run out
             of paper;
          3) protocol incompatibility between the fax modem and the fax
             machine (see TN #117).

Punkt 3) ist gar nicht so unwahrscheinlich.

Es gibt bei hylafax.org eine Mailingliste mit Archiv. Dort ist das 
Problem auch des�fteren zu finden. Nach einer evt. m�glichen L�sung 
kannst Du dort suchen.



-- 
Zum AUSTRAGEN schicken Sie eine Mail an [EMAIL PROTECTED]
mit dem Subject "unsubscribe". Probleme? Mail an [EMAIL PROTECTED] (engl)

Antwort per Email an