I am using the following piece of code on a Test server and am trying to install it on the Production server.
with dm.qryUpdate do begin SQL.Clear; Sql.Add('Insert into EffluentLevels'); Sql.Add('(DT,EFFLUENT,EFFLUENTMULTIPLIER,SEWAGE,SEWAGEMULTIPLIER,FLUSH1, FLUSH1MULTIPLIER,TOTALEFFLUENT,TOTALEFFLUENTMUILTIPLIER,TOTALCHIP,TOTALC HIPMULTIPLIIER)'); Sql.Add('Values (:DT,:EFFLUENT,:EFFLUENTMULTIPLIER,:SEWAGE,:SEWAGEMULTIPLIER,:FLUSH1,:FL USH1MULTIPLIER,:TOTALEFFLUENT,:TOTALEFFLUENTMUILTIPLIER,:TOTALCHIP,:TOTA LCHIPMULTIPLIIER)'); ParamByName('DT').AsDate := EffluentRec.DT; //This works on TestDB ParamByName('EFFLUENT').AsInteger := EffluentRec.effluent; ParamByName('EFFLUENTMULTIPLIER').AsInteger := EffluentRec.effluentMultiplier; ParamByName('SEWAGE').AsInteger := EffluentRec.sewage; ParamByName('SEWAGEMULTIPLIER').AsInteger := EffluentRec.sewageMultiplier; ParamByName('FLUSH1').AsInteger := EffluentRec.flush1; ParamByName('FLUSH1MULTIPLIER').AsInteger := EffluentRec.flush1Multiplier; ParamByName('TOTALEFFLUENT').AsInteger := EffluentRec.totalEffluent; ParamByName('TOTALEFFLUENTMUILTIPLIER').AsInteger := EffluentRec.totalEffluentMuiltiplier; ParamByName('TOTALCHIP').AsInteger := EffluentRec.totalChip; ParamByName('TOTALCHIPMULTIPLIIER').AsInteger := EffluentRec.totalChipMultipliier; ExecSQL; end; It works in the test environment but not on the Production Database. It gives an error 'Unassigned Code'. I have tracked the error down to the line of code ParamByName('DT').AsDate := EffluentRec.DT; Both databases would appear to be identical... InterBase/x86/Windows NT (access method), version "WI-V7.5.1.162" InterBase/x86/Windows NT (remote server), version "WI-V7.5.1.162/tcp (rpnlrng12)/P14" InterBase/x86/Windows NT (remote interface), version "WI-V7.5.0.174/tcp (rngd99tta06)/P14" on disk structure version 11.2 and both using dialect 1. I believe this points to being a database setting yet all settings appear to be identical in IBMonitor. Not sure what to look for now or where to look. Anyone out there with any like experiences or ideas? Regards Phil Hayward System Analyst Pinepanels Rangiora ph (64) 3 313-2764 fax (64) 3 313-2739 Ext 38824 [EMAIL PROTECTED] DISCLAIMER: This electronic message together with any attachments is confidential. If you are not the intended recipient, do not copy, disclose or use the contents in any way. Please also advise us by return e-mail that you have received the message and then please destroy. Carter Holt Harvey is not responsible for any changes made to this message and / or any attachments after sending by Carter Holt Harvey. We use virus scanning software but exclude all liability for viruses or anything similar in this email or any attachment. _______________________________________________ Delphi mailing list Delphi@ns3.123.co.nz http://ns3.123.co.nz/mailman/listinfo/delphi