Brett Wooldridge wrote:
On Thu, Jul 30, 2009 at 9:49 PM, Kathey Marsden <[email protected] <mailto:[email protected]>> wrote:

    Brett Wooldridge wrote:

        I never see the XJ001 logged, thought it appears to travel
over the wire (looking at the DRDA trace) to the client.
At first I thought we might be hitting DERBY-1191 where some errors don't get logged and indeed we may be, but looking at the places where we throw the error that the stream cannot be reused, I think we should log something. If not set already, could you try setting:
derby.stream.error.logSeverityLevel=0
derby.language.logStatementText=true

in derby.properites or in a system property and then reproduce and then double check the derby.log and see if there are any stack traces of interest?